Abatement Technologies AIRE GUARDIAN® AG8000PAS-RPM Mobile Dust Containment Cart
Tax included
in stock
The Ultimate ICRA-Compliant Solution for Containing Airborne Particles Released During Ceiling Cavity Work
Protect Your Patients. Protect Your Employees. Protect Your Facility.
Does the proximity of your hospital construction, renovation or maintenance project pose the potential risk of exposing sensitive patients or hospital staff to health-threatening airborne dust particles? The AIRE GUARDIAN® AG8000PAS-RPM Mobile Construction Containment Enclosure* from Abatement Technologies® provides the perfect particle control solution for these projects. Hospital contractors are reporting substantial productivity increases and rapid ROI on their investment in the AIRE GUARDIAN® dust containment module. This model includes PAS750 Portable Air Scrubber & RPM-RT1 Room Pressure Monitor.
* U.S. Patent No. 9,574,399 / Canadian Patents No. 2,895,016
Responsible hospital maintenance staff and facility contractors choose dust containment procedures that comply with Joint Commission audited and enforced ICRA Construction Guidelines. Infection control risks can be especially high for healthcare construction and maintenance activities that require frequent or repeated access into dust laden ceiling cavities.
Applicable uses for the AG8000PAS-RPM Mobile Dust Containment Cart with PAS750 Portable Air Scrubber and RPM-RT1 Room Pressure Monitor include:
-
Ceiling tile or grid replacement
-
Computer cable installation
-
Electrical equipment
-
Electrical wiring installation
-
Fire suppression systems
-
HVAC equipment & ductwork
-
Air filter change-outs
-
Pneumatic systems
-
Hospital automation systems
-
Facility automation networks
-
Lighting equipment
-
Plumbing systems
When used with a PAS750 Portable Air Scrubber (included in AG8000PAS-RPM kit), your workspace becomes a fortress under negative pressure surpassing hospital infection control department requirements and NFPA life safety codes for patient protection. Contractors and facility maintenance staff working on building construction and renovation projects depend on its rugged and durable design, ease of use and numerous built-in safety and performance features.
Dimensions (L x W x H) |
62”L x 32”W (157cm x 81cm) Maximum Accessible Ceiling Height:124” (3m) Minimum Height When Lowered: 77.5” (197cm)
|
Maximum Accessible Ceiling Height |
124” (3m)
|
Load Rating |
Cart base 900 lbs (408kg) Ladder 300 lbs. (136kg)
|
Door Opening |
54.5”H x 22”W (138cm x 56cm)
|
Sleeve and Top Cover Material |
Polyester (meets CPAI 84 Flame Retardant Standard) Ladder 3 section fiberglass ladder, extends to 15’H ( 4.47m) and compacts to 6’H ( 1.82m)
|
PAS750 Dimensions |
23.75”L x 18”W x 17.5”H
|
Ladder |
16 ft
|